Zk-pp2k Manual ((install)) Info
Understanding the hardware limits ensures safe and accurate operation. DC 3.3V to 30V Frequency Range: 1Hz to 150kHz Frequency Accuracy: ~2% accuracy across all ranges Duty Cycle Range: 0% to 100% Output Current: Driving capacity around 30mA Pulse Count Range: 1 to 9999, or infinite Delay Time Range: 0.000s to 9999s 🕹️ Device Layout and Interface
Equal to the input supply voltage (Internal rails are directly connected). Physical Dimensions: 79mm × 43mm × 26mm. Notable Features
This is the module's default setting. In , the display shows a percentage (e.g., "50%"). In this mode, you can adjust two main parameters: Zk-pp2k Manual
The screen will show P_ (PULSE) or % (PWM) to indicate the current mode. Setting Parameters in PWM Mode
With dual working modes and a wide voltage range (3.3V ~ 30V), this device is a staple for engineers, hobbyists, and automation technicians. 1. Technical Specifications ZK-PP2K (High Power Version) Understanding the hardware limits ensures safe and accurate
This is the factory default mode. It is ideal for applications where the output signal runs continuously, such as for motor speed regulation or dimming an LED.
The shows the negative pulse width duration. Adjust this using the N+ and N- buttons. Notable Features This is the module's default setting
This section provides a practical guide to getting the ZK-PP2K up and running.