Caraflo V200 Shower Instructions Jun 2026
Insert the brass threaded tails into the supply lines, ensuring you use appropriate plumbing washers or thread-seal tape to create a watertight seal.
The Caraflo V200 is designed for a simple surface-mount fit inside holiday homes manufactured by Swift, Willerby, ABI, and others. It is highly compatible with prefabricated shower pods made by Lamplas, Bridgewood, and Plast-Tech. Step 1: Isolate the Water Supplies
This was buried in the fine print. After thermal mapping, you have exactly 17 seconds of ideal-temperature water. Use it wisely. Arthur lunged for the shampoo. He got one armpit lathered before the water turned to a lukewarm mist.
Uses thermostatic control to maintain consistent water temperature, preventing sudden blasts of hot or cold water. Standard Operation: caraflo v200 shower instructions
Refit the handle onto the spindle so that the 38°C mark (or safety button alignment) aligns perfectly with the reference mark on the valve body.
Do you need assistance identifying ?
If you encounter issues with your Caraflo V200 shower, refer to the troubleshooting guide below: Insert the brass threaded tails into the supply
Caraflo V200 is a thermostatic shower mixer valve commonly used in static caravans and holiday homes. Below are instructions for its installation, use, and winter maintenance. Installation Instructions
The is a popular, compact thermostatic mixer valve widely utilized in caravans, motorhomes, and marine applications. Designed specifically for static and touring vehicles, it delivers precise temperature control even with fluctuating water pressures. This guide provides complete step-by-step instructions for installing, operating, and maintaining your Caraflo V200 shower unit. Technical Specifications
Use PTFE thread-sealing tape on the threads to ensure a watertight seal. Verify that the connectors are level using a spirit level. Step 3: Mount the Valve Body Step 1: Isolate the Water Supplies This was
38°C (with safety override button)
The V200 requires a standard two-hole mount with a consistent center-to-center measurement (usually around 100mm to 110mm, but verify with your unit).
As a TMV2-approved valve, the Caraflo V200 requires an annual test to ensure it continues to operate safely. This must be carried out by a suitably qualified competent person.
15mm compression or 1/2" BSP threads (depending on the specific sub-model variant) Inlet Centers: 150mm standard pipe spacing Pre-Installation Requirements
| Problem | Possible Cause | Solution | | :--- | :--- | :--- | | | Power source issue (dead batteries) or no water supply. | Replace batteries (usually AA inside the control box) or check main water valves. | | Water is too cold | Hot water supply cut off or inlet filters blocked. | Check if the water heater is working. Clean the hot water inlet strainer. | | Temperature fluctuates | Unbalanced water pressure or dirty thermostatic cartridge. | Ensure no other appliances (washing machine/toilet) are using water simultaneously while showering. Clean cartridge. | | LED Display fading | Low battery voltage. | Replace batteries immediately to prevent the valve from sticking in the "open" position. | | Water drips after shut off | Residual water in the pipe. | This is normal for a few seconds. If it persists, the internal solenoid valve may need cleaning or replacement. |